Evaporative & Outdoor Cooling SpecialistsPatio & Warehouse Cooling
Expert Maintenance for Desert Coolers, Misting Lines & Fogging Systems in Dubai. We fix Pumps, Nozzles, and Leaks.
- 1. Desert Cooler Repair
- 2. Misting System Fix
- 3. Pump Replacement
- 4. Nozzle Unblocking
- 5. Honeycomb Pad Change
Cooling System Repairs
Recent maintenance of Misting Lines, Desert Coolers, and Industrial Fans across Dubai.
Misting Pump Oil Change

.png?updatedAt=1768283338644)
Diagnosis & Solution
High-pressure misting pump (1000 PSI) was overheating. Drained old milky oil, replaced seals, and refilled with SAE-30 non-detergent pump oil.
Industrial Cooler Belt

.png?updatedAt=1768283337694)
Diagnosis & Solution
Rooftop cooler fan was making a loud screeching noise. Replaced the worn-out B-section V-belt and aligned the motor pulley to eliminate vibration.
Honeycomb Pad Replacement

.png?updatedAt=1768283340501)
Diagnosis & Solution
Portable coolers were not cooling effectively. Old honeycomb pads were clogged with calcium scale. Installed new 100mm thick cellulose pads.
Nozzle Replacement

.png?updatedAt=1768283337867)
Diagnosis & Solution
Misting line had uneven spray. Found 15 nozzles completely blocked by hard water deposits. Replaced with new 0.2mm anti-drip brass nozzles.
Water Tank Leak Fix

.png?updatedAt=1768283338775)
Diagnosis & Solution
Desert cooler was leaking water onto the patio. Found a crack in the fiberglass tank. Applied marine-grade epoxy patch and sealed the drain plug.
Live Telemetry & Logistics
Real-time coordination of our 17 specialist teams across Dubai.
Misting & Evaporative Repair
We provide expert repair and maintenance for Misting Lines, Desert Coolers, and Industrial Fans. From pump replacement to nozzle cleaning, we handle it all.
1Portable Desert Cooler
Mobile cooling units for outdoor seating, tents, and small workshops.

Technical Information
Plastic body with large water tank and honeycomb cooling pads. Uses natural evaporation to cool air without gas.
Working Principle
A submersible pump wets the honeycomb pads, and a fan pulls hot air through them, instantly reducing temperature.
Maintenance & Repair Services
Hygiene
- Tank & Pad sanitization
- Sludge removal
- Odor elimination treatment
Mechanical
- Submersible pump replacement
- Castor wheel repair
- Fan blade balancing
2Industrial Ducted Cooler
Heavy-duty rooftop units for factories, warehouses, and open kitchens.

Technical Information
Metal body installed on rooftops. Connects to ductwork. Uses heavy-duty belts, pulleys, and large blower fans.
Working Principle
Delivers massive CFM of cooled fresh air. Requires precise float valve adjustment to maintain water levels.
Maintenance & Repair Services
Drive System
- Fan belt tensioning & alignment
- Motor bearing lubrication
- Pulley alignment
Water System
- Float valve adjustment
- Water distribution pipe clean
- Leak proofing
3High-Pressure Misting Line
Luxury outdoor cooling for pergolas, restaurants, and villas.

Technical Information
Uses a high-pressure pump (1000 PSI) and stainless steel pipes with ruby-orifice nozzles.
Working Principle
Water is pressurized to create ultra-fine mist (flash evaporation) that cools the air without wetting surfaces.
Maintenance & Repair Services
Nozzle Care
- Nozzle chemical descaling
- Anti-drip valve check
- Orifice cleaning
High Pressure
- Pump oil change (500 hrs)
- SS Pipe leakage repair
- Pressure regulation
4Misting Fans
Versatile spot cooling for events, poolsides, and patios.

Technical Information
Industrial fan integrated with a misting ring or localized water tank. Mobile and effective.
Working Principle
Combines high-velocity airflow with mist to provide wind-chill cooling in specific zones.
Maintenance & Repair Services
Fan Repair
- Fan motor rewinding
- Oscillation gear fix
- Guard cleaning
Mist System
- Mist ring cleaning
- Nozzle unclogging
- Feed tube replacement
5Pumps & Filtration System
The heart of evaporative cooling. Clean water ensures longevity.

Technical Information
Critical Issues: 'Scale Buildup' (Salt deposits on pads/nozzles), 'Pump Burnout' (Low water level).
Working Principle
Filtration removes sediment and calcium before water reaches the sensitive pump and nozzles.
Maintenance & Repair Services
Filtration
- Sediment filter replacement
- Water softener installation
- Scale inhibitor dosing
Pump Works
- High-pressure pump seal fix
- Solenoid valve replacement
- Oil seal change
Evaporative System Care
Blocked nozzles and dirty tanks reduce cooling efficiency and breed bacteria. Our focus is on Deep Sanitization & Descaling.
Deep Tank & Pad Sanitization
Stagnant water causes bad smells and bacteria (Legionella). We drain the tank, scrub the sludge, and chemical-wash honeycomb pads.
Misting Nozzle Descaling
Blocked nozzles stop misting. We remove and soak nozzles in acidic descaling solution to dissolve calcium and salt deposits.
Annual Maintenance Contract (AMC)
Ensure your outdoor area is ready for summer. Includes pump oil change, belt adjustment, and pre-season cleaning.
Service Packages
Transparent Rates for Coolers & Misting Systems. No hidden fees.
Cooler Service
- Honeycomb Pad Cleaning
- Tank Sludge Removal
- Belt Tension Check
- Water Pump Check
Misting System Service
- Nozzle Descaling (up to 20)
- Filter Cartridge Clean
- Pump Oil Check
- Line Flushing
Pump Replacement
- New Pump Unit
- Submersible or High-Pressure
- Installation Labor
- Pressure Testing
Recent Projects
Restoring outdoor comfort in Dubai villas and restaurants.
BEFORE
AFTERRestaurant Terrace - Misting Failure
Problem: Nozzles dripping water instead of misting. Customers getting wet due to calcium buildup inside nozzles.
Solution: Descaled all 40 nozzles in acid bath, replaced the sediment filter, and serviced the high-pressure pump valves.
Result: Perfect fine mist restored, outdoor seating usable again.
BEFORE
AFTERWarehouse - Industrial Cooler Noise
Problem: Loud screeching noise from rooftop unit. Loose fan belt and dry motor bearings.
Solution: Tightened V-belt tension, aligned the pulley, and greased motor bearings.
Result: Cooler running silently with improved airflow.
Digital Job Card
We provide a digital service report after every visit. You'll see the pump oil condition, nozzle status, and water pressure readings.
System Diagnostics
Water Pressure (PSI), Oil Level, and Filter Status logged.
WhatsApp Updates
Receive your invoice and report directly on your phone.
Job Card #2024
Generated on 15 Nov 2024
Technician Notes:
Misting pump oil changed. 15 nozzles descaled. Filter replaced.
System Lifespan & Care

Portable Coolers
Typical lifespan: 3-5 years. Regular tank cleaning prevents bacterial growth and pump failure.

Misting Pumps
Typical lifespan: 5-7 years. Oil changes every 500 hours are critical for high-pressure systems.

Common Issues
Bad smells (bacteria), blocked nozzles (salt buildup), and loud pump noise are common issues we solve.

UNITECH Outdoor Cooling
Misting & Cooling Engineers in Dubai • Open 24 Hours
Omar Al Futtaim
Local Guide · 2 days ago
Our restaurant terrace was unusable in July. UNITECH installed a High-Pressure Misting System and now it's pleasant outside. They serviced the pump and replaced clogged nozzles quickly.
Thank you Mr. Omar. Keeping your patrons cool is our priority.
Sarah Jenkins
Local Guide · 3 days ago
My villa's Desert Cooler stopped working. They arrived within an hour, diagnosed a burnt submersible pump, and replaced it. They also sanitized the tank.
Rajesh Kumar
Local Guide · 1 week ago
We have large Industrial Coolers for our warehouse. UNITECH adjusted the belts and greased the bearings. The screeching noise is gone and airflow is much better.
Ahmed Bin Sultan
Local Guide · 2 weeks ago
The misting line in my pergola was dripping water. They performed a chemical descaling of the Ruby Nozzles and fixed the anti-drip valves. No more wet floor.
Glad we could help, Ahmed. Regular descaling is key for misting systems.
Robert D'Souza
Local Guide · 1 month ago
Our cooler tank was leaking. They patched the fiberglass and replaced the float valve. Professional service and very clean work.
What Our Clients Say
"Our outdoor misting system stopped working right before the weekend. UNITECH came, cleaned the nozzles, and changed the oil. Saved our Friday brunch!"
Mr. Thomas
Restaurant Manager, Dubai Marina
"My desert cooler smelled terrible. They drained the tank, scrubbed it clean, and put in fresh pads. Now the air smells fresh and cool."
Ali Al Hassan
Villa Owner, Arabian Ranches
"We have 10 industrial coolers. They maintain the belts and pumps regularly. The team is knowledgeable about evaporative cooling."
Logistics Supervisor
Warehouse, DIP
Frequently Asked Questions
Do you serve commercial buildings?
Yes, we specialize in Rooftop Package Units for malls, offices, and warehouses.
Is your work guaranteed?
Yes, we provide a 1-month warranty on service and up to 1-year warranty on replaced compressors.
How quickly can you arrive?
For emergencies in Dubai, our target arrival time is under 90 minutes.
Why is chemical cleaning necessary?
Water alone cannot remove the salt and dust cemented onto the aluminum fins. Chemical foam lifts this grime to restore heat exchange efficiency.