UNITECH | HVAC Specialists Dubai
Dubai’s Licensed Misting & Cooling Experts | Trade License No: 134585 ISO Compliant Safety Protocols
Outdoor Misting System
Outdoor Cooling Team arriving in 46 minutes
Rated 4.9/5 by Villa & Restaurant Owners

Evaporative & Outdoor Cooling SpecialistsPatio & Warehouse Cooling

Expert Maintenance for Desert Coolers, Misting Lines & Fogging Systems in Dubai. We fix Pumps, Nozzles, and Leaks.

  • 1. Desert Cooler Repair
  • 2. Misting System Fix
  • 3. Pump Replacement
  • 4. Nozzle Unblocking
  • 5. Honeycomb Pad Change
Outdoor Projects

Cooling System Repairs

Recent maintenance of Misting Lines, Desert Coolers, and Industrial Fans across Dubai.

Misting Pump Oil Change

Palm Jumeirah Villa
Technical Diagnosis
Before
Resolved State
After

Diagnosis & Solution

High-pressure misting pump (1000 PSI) was overheating. Drained old milky oil, replaced seals, and refilled with SAE-30 non-detergent pump oil.

Status Report
Fixed

Industrial Cooler Belt

Al Quoz Warehouse
Technical Diagnosis
Before
Resolved State
After

Diagnosis & Solution

Rooftop cooler fan was making a loud screeching noise. Replaced the worn-out B-section V-belt and aligned the motor pulley to eliminate vibration.

Status Report
Fixed

Honeycomb Pad Replacement

Events Tent Jebel Ali
Technical Diagnosis
Before
Resolved State
After

Diagnosis & Solution

Portable coolers were not cooling effectively. Old honeycomb pads were clogged with calcium scale. Installed new 100mm thick cellulose pads.

Status Report
Fixed

Nozzle Replacement

Downtown Cafe Terrace
Technical Diagnosis
Before
Resolved State
After

Diagnosis & Solution

Misting line had uneven spray. Found 15 nozzles completely blocked by hard water deposits. Replaced with new 0.2mm anti-drip brass nozzles.

Status Report
Fixed

Water Tank Leak Fix

Mirdif Villa
Technical Diagnosis
Before
Resolved State
After

Diagnosis & Solution

Desert cooler was leaking water onto the patio. Found a crack in the fiberglass tank. Applied marine-grade epoxy patch and sealed the drain plug.

Status Report
Fixed
Live Fleet Status: Online

Live Telemetry & Logistics

Real-time coordination of our 17 specialist teams across Dubai.

Active
09+
On-Site
Standby
08
Available
Sector: Dubai South & North
JumeirahUmm SuqeimAl BarshaArabian RanchesAl Quoz+3 more
Dispatch LogLive
Arabian Ranches
Misting Pump
In Progress
Jumeirah Park
Pad Replacement
Finishing
Dubai Marina
Nozzle Block
Dispatched
Palm Jumeirah
Leakage Fix
In Progress
Meadows
AMC Visit
Scheduled
Check Availability in Your Area
Outdoor Cooling Solutions

Misting & Evaporative Repair

We provide expert repair and maintenance for Misting Lines, Desert Coolers, and Industrial Fans. From pump replacement to nozzle cleaning, we handle it all.

1Portable Desert Cooler

Mobile cooling units for outdoor seating, tents, and small workshops.

1. Portable Desert Cooler

Technical Information

Plastic body with large water tank and honeycomb cooling pads. Uses natural evaporation to cool air without gas.

Working Principle

A submersible pump wets the honeycomb pads, and a fan pulls hot air through them, instantly reducing temperature.

Maintenance & Repair Services

Hygiene
  • Tank & Pad sanitization
  • Sludge removal
  • Odor elimination treatment
Mechanical
  • Submersible pump replacement
  • Castor wheel repair
  • Fan blade balancing

2Industrial Ducted Cooler

Heavy-duty rooftop units for factories, warehouses, and open kitchens.

2. Industrial Ducted Cooler

Technical Information

Metal body installed on rooftops. Connects to ductwork. Uses heavy-duty belts, pulleys, and large blower fans.

Working Principle

Delivers massive CFM of cooled fresh air. Requires precise float valve adjustment to maintain water levels.

Maintenance & Repair Services

Drive System
  • Fan belt tensioning & alignment
  • Motor bearing lubrication
  • Pulley alignment
Water System
  • Float valve adjustment
  • Water distribution pipe clean
  • Leak proofing

3High-Pressure Misting Line

Luxury outdoor cooling for pergolas, restaurants, and villas.

3. High-Pressure Misting Line

Technical Information

Uses a high-pressure pump (1000 PSI) and stainless steel pipes with ruby-orifice nozzles.

Working Principle

Water is pressurized to create ultra-fine mist (flash evaporation) that cools the air without wetting surfaces.

Maintenance & Repair Services

Nozzle Care
  • Nozzle chemical descaling
  • Anti-drip valve check
  • Orifice cleaning
High Pressure
  • Pump oil change (500 hrs)
  • SS Pipe leakage repair
  • Pressure regulation

4Misting Fans

Versatile spot cooling for events, poolsides, and patios.

4. Misting Fans

Technical Information

Industrial fan integrated with a misting ring or localized water tank. Mobile and effective.

Working Principle

Combines high-velocity airflow with mist to provide wind-chill cooling in specific zones.

Maintenance & Repair Services

Fan Repair
  • Fan motor rewinding
  • Oscillation gear fix
  • Guard cleaning
Mist System
  • Mist ring cleaning
  • Nozzle unclogging
  • Feed tube replacement

5Pumps & Filtration System

The heart of evaporative cooling. Clean water ensures longevity.

5. Pumps & Filtration System

Technical Information

Critical Issues: 'Scale Buildup' (Salt deposits on pads/nozzles), 'Pump Burnout' (Low water level).

Working Principle

Filtration removes sediment and calcium before water reaches the sensitive pump and nozzles.

Maintenance & Repair Services

Filtration
  • Sediment filter replacement
  • Water softener installation
  • Scale inhibitor dosing
Pump Works
  • High-pressure pump seal fix
  • Solenoid valve replacement
  • Oil seal change
Preventive Maintenance

Evaporative System Care

Blocked nozzles and dirty tanks reduce cooling efficiency and breed bacteria. Our focus is on Deep Sanitization & Descaling.

Deep Tank & Pad Sanitization

Stagnant water causes bad smells and bacteria (Legionella). We drain the tank, scrub the sludge, and chemical-wash honeycomb pads.

Sludge removal
Anti-bacterial treatment
Pad pressure wash
Odor elimination

Misting Nozzle Descaling

Blocked nozzles stop misting. We remove and soak nozzles in acidic descaling solution to dissolve calcium and salt deposits.

Nozzle unclogging
Line flushing
Anti-drip valve check
Filter cleaning

Annual Maintenance Contract (AMC)

Ensure your outdoor area is ready for summer. Includes pump oil change, belt adjustment, and pre-season cleaning.

3 Seasonal visits
Pump protection check
Free minor parts
Water quality test

Service Packages

Transparent Rates for Coolers & Misting Systems. No hidden fees.

Cooler Service

AED 150 - 250
  • Honeycomb Pad Cleaning
  • Tank Sludge Removal
  • Belt Tension Check
  • Water Pump Check
Most Popular

Misting System Service

AED 250 - 450
  • Nozzle Descaling (up to 20)
  • Filter Cartridge Clean
  • Pump Oil Check
  • Line Flushing

Pump Replacement

AED 350 - 1,500+
  • New Pump Unit
  • Submersible or High-Pressure
  • Installation Labor
  • Pressure Testing

Recent Projects

Restoring outdoor comfort in Dubai villas and restaurants.

BeforeBEFORE
AfterAFTER

Restaurant Terrace - Misting Failure

Jumeirah Beach Road

Problem: Nozzles dripping water instead of misting. Customers getting wet due to calcium buildup inside nozzles.

Solution: Descaled all 40 nozzles in acid bath, replaced the sediment filter, and serviced the high-pressure pump valves.

Result: Perfect fine mist restored, outdoor seating usable again.

BeforeBEFORE
AfterAFTER

Warehouse - Industrial Cooler Noise

Al Quoz Industrial

Problem: Loud screeching noise from rooftop unit. Loose fan belt and dry motor bearings.

Solution: Tightened V-belt tension, aligned the pulley, and greased motor bearings.

Result: Cooler running silently with improved airflow.

Service Report

Digital Job Card

We provide a digital service report after every visit. You'll see the pump oil condition, nozzle status, and water pressure readings.

System Diagnostics

Water Pressure (PSI), Oil Level, and Filter Status logged.

WhatsApp Updates

Receive your invoice and report directly on your phone.

Job Card #2024

Generated on 15 Nov 2024

Technician Notes:

Misting pump oil changed. 15 nozzles descaled. Filter replaced.

Attachment: ServiceReport.pdf

System Lifespan & Care

Portable Cooler

Portable Coolers

Typical lifespan: 3-5 years. Regular tank cleaning prevents bacterial growth and pump failure.

Misting Pump

Misting Pumps

Typical lifespan: 5-7 years. Oil changes every 500 hours are critical for high-pressure systems.

Issues

Common Issues

Bad smells (bacteria), blocked nozzles (salt buildup), and loud pump noise are common issues we solve.

Google Maps

UNITECH Outdoor Cooling

4.9
322 Google reviews

Misting & Cooling Engineers in Dubai • Open 24 Hours

O

Omar Al Futtaim

Local Guide · 2 days ago

Outdoor Cooling

Our restaurant terrace was unusable in July. UNITECH installed a High-Pressure Misting System and now it's pleasant outside. They serviced the pump and replaced clogged nozzles quickly.

Response from the owner

Thank you Mr. Omar. Keeping your patrons cool is our priority.

S

Sarah Jenkins

Local Guide · 3 days ago

Desert Cooler

My villa's Desert Cooler stopped working. They arrived within an hour, diagnosed a burnt submersible pump, and replaced it. They also sanitized the tank.

Rajesh Kumar

Rajesh Kumar

Local Guide · 1 week ago

Industrial Cooler

We have large Industrial Coolers for our warehouse. UNITECH adjusted the belts and greased the bearings. The screeching noise is gone and airflow is much better.

A

Ahmed Bin Sultan

Local Guide · 2 weeks ago

Fogging System

The misting line in my pergola was dripping water. They performed a chemical descaling of the Ruby Nozzles and fixed the anti-drip valves. No more wet floor.

Response from the owner

Glad we could help, Ahmed. Regular descaling is key for misting systems.

R

Robert D'Souza

Local Guide · 1 month ago

Water Tank

Our cooler tank was leaking. They patched the fiberglass and replaced the float valve. Professional service and very clean work.

What Our Clients Say

"Our outdoor misting system stopped working right before the weekend. UNITECH came, cleaned the nozzles, and changed the oil. Saved our Friday brunch!"

Mr. Thomas

Restaurant Manager, Dubai Marina

"My desert cooler smelled terrible. They drained the tank, scrubbed it clean, and put in fresh pads. Now the air smells fresh and cool."

Ali Al Hassan

Villa Owner, Arabian Ranches

"We have 10 industrial coolers. They maintain the belts and pumps regularly. The team is knowledgeable about evaporative cooling."

Logistics Supervisor

Warehouse, DIP

Frequently Asked Questions

Do you serve commercial buildings?

Yes, we specialize in Rooftop Package Units for malls, offices, and warehouses.

Is your work guaranteed?

Yes, we provide a 1-month warranty on service and up to 1-year warranty on replaced compressors.

How quickly can you arrive?

For emergencies in Dubai, our target arrival time is under 90 minutes.

Why is chemical cleaning necessary?

Water alone cannot remove the salt and dust cemented onto the aluminum fins. Chemical foam lifts this grime to restore heat exchange efficiency.

Live Update: Out of 17 Outdoor Cooling teams:

09+ working on-site (Busy).

08 waiting for your call!